Chinese Journal of Orthopaedics ; (12): 97-103, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993415

RESUMO

Objective:To investigate the effect of 3D-printed customized flanged cup in hip revision with severe acetabular bone defects.Methods:Since February 2017, 10 cases of 3D-printed customized flanged cups were used in hip revision with severe acetabular bone defects, including 2 cases of Paprosky type IIIA and 8 cases of Paprosky type IIIB. There were 5 males and 5 females, mean age 73.6±8.1 yrs (range, 62-87 yrs), 5 left and 5 right cases. The preoperative thin-layer CT scan was preformed to reverse reconstruct digital pelvis. Five cases of one-piece flanged cups and 5 cases of decomposed flanged cups, including 3 cases of composite one-piece cups were designed by computer. The surgery was performed strictly according to the plan.Postoperative follow-up was performed to evaluate the Harris score. Operation time,intraoperative bleeding and other complications such as vascular and nerve injury, postoperative infection, and dislocation were counted. Pelvic X-ray was used to assess the height and horizontal position of the center of rotation and the stability of the prosthesis.Results:The surgical procedure was successful, with an average operative time of 147.9±48.3 min (range, 96-212 min) and an average intraoperative bleeding of 730.4±262.6 ml (range, 500-1 300 ml). The mean time of final follow-up was 40.8±18.7 months (range, 16-70 months) after surgery. At the last follow-up, the average Harris score was 83.80±6.73, with 4 cases excellent, 5 cases good, and 1 case fair. The excellent and good rate was 90%. The last Harris score was significantly higher than that before operation 28.60±8.40 ( t=16.84, P<0.001). The height of affected hip joint rotation center decreased from 46.24±7.74 mm before operation to 15.54±2.54 mm after operation with significant difference ( t=14.61, P<0.001). It was slightly higher than the opposite side (13.81±1.48 mm), which had no significant difference ( t=1.83, P=0.100). The horizontal distance of affected hip joint rotation center increased from 33.79±5.27 mm before operation to 40.53±4.50 mm after operation with significant difference ( t=3.62, P=0.006). It had no significant difference ( t=1.28, P=0.232) compared with the opposite side (38.54±3.46 mm). All incisions were healed in one stage without infection, vascular or nerve injury. During the following-up, all prostheses were in satisfied position without loosening, dislocation or screw breaks. Conclusion:Digitally assisted 3D-printed flanged cups can be used in hip revision with severe acetabular bone defect. It can not only improve hip joint function, but also restore the acetabular rotation center and the prosthesis stability, which can achieve good early and mid-term effect.

2.
Chinese Journal of Hospital Administration ; (12): 608-610, 2017.
Artigo em Chinês | WPRIM | ID: wpr-611741

RESUMO

The authors described the architecture of a real-time platform designed to monitor medical equipments.Three types of data collectors were employed to collect information into the background servers for real-time analysis and presentation.Such a platform can effectively enable the hospital to manage its medical equipments, for their positioning, assets management and risk control.

3.
China Medical Equipment ; (12): 59-61,62, 2015.
Artigo em Chinês | WPRIM | ID: wpr-602795

RESUMO

Objective:Using analytic hierarchy process(AHP)method to construct the risk evaluation of medical equipment.Methods: Combine the professors’ suggestion, data of maintenance and quality control to several medical equipments in different hospitals. Screen six kinds of medical equipment, including infant incubator, high-frequency electrotome, defibrillator, ECG monitor, ventilator and infusion pumps.Results: Ventilator has highest risk and need to be concentrated.Conclusion: The results can guide quality control, patrol, and maintenance.

4.
China Medical Equipment ; (12): 76-79, 2014.
Artigo em Chinês | WPRIM | ID: wpr-443562

RESUMO

Objective: To find the reason of risk on medical equipment. Methods: Based on RCA, to adopt the event classification to evaluate the X-ray equipment, high-frequency electro tome, electro-cardiac monitor, infusion pump, ventilator, defibrillators and infant incubator, discuss the root cause of medical risk. Results:To deduce the medical equipment risk by PM and quality control. Conclusion:With the analysis of quality control, the application of RCA is gradually explained in management of medical equipment.

5.
International Journal of Biomedical Engineering ; (6): 247-250, 2009.
Artigo em Chinês | WPRIM | ID: wpr-393087

RESUMO

With the improvement of living standard, the requirement of artificial joint material is ever increasing. The development of meted artificial joint, high polymer artificial joint and ceramic-made artificial joint, which are widely used in joint replacement, are introduced. Advantages and disadvantages of these materials are discussed, as well as the required improvement to these three materials. Development on metal-to-metal hip resurfacing arthroplasty and its clinical application is introduced. Now that no material with good biocompatibility, good biomechanical compatibility, good biological aasociativity and satisfied life-span has yet been found, compound material artificial joint may be the focus of the research in future.